In this Act, unless there is anything repugnant in the subject or context,-- 1[(a) "accident" means an explosion of boiler, or boiler component, which is calculated to weaken the strength or an uncontrolled release of water or steam therefrom, liable to cause death or injury to any person or damage to any property;] 2[(aa) "Board" means the Central Boilers Board constituted under section 27A;] 3[(b) "boiler" means a pressure vessel in which steam is generated for use external to itself by application of heat which is wholly or partly under pressure when steam is shut off but does not include a pressure vessel,-- (i) with capacity less than 25 liters (such capacity being measured from the feed check valve to the main steam stop valve); (ii) with less than one kilogram per centimeter square design gauge pressure and working gauge pressure; or (iii) in which water is heated below one hundred degrees centigrade; (ba) "boiler component" means steam piping, feed piping, economiser, superheater, any mounting or other fitting and any other external or internal part of a boiler which is subject to pressure exceeding one kilogram per centimeter square gauge;] 4[(c) "Chief Inspector", "Deputy Chief Inspector" and "Inspector" mean, respectively, a person appointed to be a Chief Inspector, a Deputy Chief Inspector and an Inspector under this Act;] 5[(ca) "Competent Authority" means an institution recognised in such manner as may be prescribed by regulations for issue of certificate to the welders for welding of boiler and boiler components; (cb) "Competent Person" means a person recognised in such manner as may be prescribed by regulations for inspection and certification of boilers and boiler components during manufacture, erection and use. All Inspectors shall be ipso facto competent persons;] 6[(cc) "economiser" means any part of a feed-pipe that is wholly or partially exposed to the action of flue gases for the purpose of recovery of waste heat; (ccc) "feed-pipe" means any pipe or connected fitting wholly or partly under pressure through which feed water passes directly to a boiler and 7[which] does not form an integral part thereof;] 8[(ccd) "Inspecting Authority" means an institution recognised in such manner as may be prescribed by regulations for the inspection and certification of boilers and boiler components during manufacture. All Chief Inspectors of Boilers shall be ipso facto Inspecting Authorities;] (cce) "manufacture" means manufacture, construction and fabrication of boiler or boiler component, or both; (ccf) "manufacturer" means a person engaged in the manufacture; (d) "owner"9[includes any person possessing or] using a boiler as agent of the owner thereof and any person using a boiler which he has hired or obtained on loan from the owner thereof; (e) "prescribed" means prescribed by regulations or rules made under this Act; 10[(f) "steam pipe" means any pipe through which steam passes if-- (i) the pressure at which steam passes through such pipe exceeds 3.5 kilogram per square centimeters above atmospheric pressure, or (ii) such pipe exceeds 254 millimeters in internal diameter and the pressure of steam exceeds 1 kilogram per square centimeters above the atmospheric pressure, and includes in either case any connected fitting of a steam-pipe;] 11[(g) "structural alteration, addition or renewal" means,-- (i) any change in the design of a boiler or boiler component; (ii) replacement of any part of boiler or boiler component by a part which does not conform to the same specification; or (iii) any addition to any part of a boiler or boiler component; (h) "superheater" means any equipment which is partly or wholly exposed to flue gases for the purpose of raising the temperature of steam beyond the saturation temperature at that pressure and includes a re-heater; (i) "Technical Adviser" means the Technical Adviser appointed under sub-section (1) of section 4A.]
<span style="margin-left:15px;"></span>In this Act, unless there is anything repugnant in the subject or context,--<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> <sup>1</sup>[(a) "accident" means an explosion of boiler, or boiler component, which is calculated to weaken the strength or an uncontrolled release of water or steam therefrom, liable to cause death or injury to any person or damage to any property;]<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> <sup>2</sup>[(aa) "Board" means the Central Boilers Board constituted under section 27A;]<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> <sup>3</sup>[(b) "boiler" means a pressure vessel in which steam is generated for use external to itself by application of heat which is wholly or partly under pressure when steam is shut off but does not include a pressure vessel,--<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (i) with capacity less than 25 liters (such capacity being measured from the feed check valve to the main steam stop valve);<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (ii) with less than one kilogram per centimeter square design gauge pressure and working gauge pressure; or<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (iii) in which water is heated below one hundred degrees centigrade;<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (ba) "boiler component" means steam piping, feed piping, economiser, superheater, any mounting or other fitting and any other external or internal part of a boiler which is subject to pressure exceeding one kilogram per centimeter square gauge;]<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> <sup>4</sup>[(c) "Chief Inspector", "Deputy Chief Inspector" and "Inspector" mean, respectively, a person appointed to be a Chief Inspector, a Deputy Chief Inspector and an Inspector under this Act;]<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> <sup>5</sup>[(ca) "Competent Authority" means an institution recognised in such manner as may be prescribed by regulations for issue of certificate to the welders for welding of boiler and boiler components;<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (cb) "Competent Person" means a person recognised in such manner as may be prescribed by regulations for inspection and certification of boilers and boiler components during manufacture, erection and use. All Inspectors shall be ipso facto competent persons;] <br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> <sup>6</sup>[(cc) "economiser" means any part of a feed-pipe that is wholly or partially exposed to the action of flue gases for the purpose of recovery of waste heat;<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (ccc) "feed-pipe" means any pipe or connected fitting wholly or partly under pressure through which feed water passes directly to a boiler and <sup>7</sup>[which] does not form an integral part thereof;]<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> <sup>8</sup>[(ccd) "Inspecting Authority" means an institution recognised in such manner as may be prescribed by regulations for the inspection and certification of boilers and boiler components during manufacture. All Chief Inspectors of Boilers shall be <i>ipso facto</i> Inspecting Authorities;]<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (cce) "manufacture" means manufacture, construction and fabrication of boiler or boiler component, or both;<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (ccf) "manufacturer" means a person engaged in the manufacture;<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (d) "owner"<sup>9</sup>[includes any person possessing or] using a boiler as agent of the owner thereof and any person using a boiler which he has hired or obtained on loan from the owner thereof;<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (e) "prescribed" means prescribed by regulations or rules made under this Act;<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> <sup>10</sup>[(f) "steam pipe" means any pipe through which steam passes if--<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span><span style="margin-left:15px;"></span>(i) the pressure at which steam passes through such pipe exceeds 3.5 kilogram per square centimeters above atmospheric pressure, or<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (ii) such pipe exceeds 254 millimeters in internal diameter and the pressure of steam exceeds 1 kilogram per square centimeters above the atmospheric pressure,<br> and includes in either case any connected fitting of a steam-pipe;]<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> <sup>11</sup>[(g) "structural alteration, addition or renewal" means,--<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (i) any change in the design of a boiler or boiler component;<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (ii) replacement of any part of boiler or boiler component by a part which does not conform to the same specification; or<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (iii) any addition to any part of a boiler or boiler component;<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (h) "superheater" means any equipment which is partly or wholly exposed to flue gases for the purpose of raising the temperature of steam beyond the saturation temperature at that pressure and includes a re-heater;<br> <span style="margin-left:15px;"></span><span style="margin-left:15px;"></span> (i) "Technical Adviser" means the Technical Adviser appointed under sub-section <i>(1)</i> of section 4A.] <br><br>